Technical Specifications
-
- pH Range : -2.000 to 20.000 pH
- Selectable Resolution : 0.1 / 0.01 / 0.001 pH
- Relative Accuracy : ±0.02 / 0.002 pH
- mV/ORP Range – mV/RmV : ±2000.0
- ORP : EH auto calibration to standard hydrogen electrode
- Resolution : 0.1
- Relative Accuracy : ±0.2 mV or 0.05%, whichever is greater.
- Slope : 80 – 120 %
- Auto Buffer Recognition :
1) 6.86 / 7.00 & 4.01 / 9.18 / 10.01 pH @ 25ºC for two points
2) 4.01, 6.86 / 7.00 & 9.18 / 10.01 pH @ 25ºC for three points - Calibration Reminder Alarm : 0-99 hours
- Result : Auto / Manual
- pH Buffer Standard : US / NIST / EURO / DIN
-
- Short Link : Provided to diagnose the problem either with Instrument OR Electrode.
- Conductivity Range :
● 0-20.00, 20-200.0, 200-2000 µS/cm, 2-20.000, 20-200, 200-2000 mS/cm for K=1.0
● 0-10.00, 10-100.0, 100-1000 µS/cm, 1-10.000, 10-100, 100-1000 mS/cm for K=0.5
● 0-2.00, 2-20.0, 20-200, 200-2000 µS/cm, 2-20, 20-200 mS/cm for K=0.1
(Range value change depending upon cell selection) - Conductivity Resolution : 0.001, 0.01, 0.1 µS/cm & 0.001, 0.01, 0.1, 1 mS/cm
- TDS Range : 0 to 10, 100, 1000, 10000 ppm, 100ppt, 1000ppt
(Depending on TDS Factor) - TDS Resolution : 0.001, 0.01, 0.1 ppm & 0.001, 0.01, 0.1 ppt (1ppt=1000ppm)
- Number of Range : Six
- Calibration Standard : Six Conductivity & TDS Standard – One Per Range
-
- Calibration Factor : Six – One Per Range
- Range Selection : Auto / Manual
- Suitable Cell Constant : 0.1, 0.5 & 1.0 K
- Adjustable Cell Constant : 0.09 to 0.11 K, 0.45 to 0.55 K & 0.90 to 1.1 K
- Conductivity to TDS Conversion : 0.40000 to 1.00000 (Adjustable Factor)
- Temperature Coefficient : Six – 0-10.000 % per °C (Adjustable) – One Per Range
- Reading : Conductivity at actual temperature and at 25°C & TDS with scrolling display.
- Temperature Range : -5.0 to 130.0°C
- Temperature Resolution : 0.1°C
- Temperature Compensation : Auto / Manual
- Temperature Calibration : In-built software and can be calibrated by users
- Calibration & Analysis : pH Mode, ORP Mode, Conductivity Mode and TDS Mode.
- Error Message : “Wrong standard / Cell”, “Cell Short”, “Cell Open”, “Try Upper Range”, “Try Lower Range”, “Bad Buffer / Electrode”, “pH Over Range”, “Temperature Probe Error”, “In-complete Calibration”, “Calibration Due”, & “Low Memory”.
- Display : 16 x 2 Line Alphanumeric Backlit LCD.
- Keypad : Membrane waterproof polyester soft keypad compliance to UL/ROHS.
- Calibration Data Storage : Non-Volatile Memory can store, print & view calibration details.
- Analysis Data Storage : More than 500 analysis data which can be viewed & Print, company name, analysis date & time, record number, *Username, *Sample Name, *Bath Number/ID, pH, mV, temperature reading, calibration data with date & time, conductivity at 25°C and conductivity at actual temperature, % Tempco, conductivity to TDS conversion factor, TDS, instrument serial number, Instrument Make & Model & *Signature etc. Secondly, analysis data can be print online without saving analysis data in Instrument.
(*: Not possible to enter data by instrument keypad but it will be handwritten) - Searching of data : With record number, batch number, date, date range and by scrolling.
- Report Formation : As per Non-GLP Compliance
- Printer Interface : Centronics Parallel Port / Serial (RS-232 C) Port
- Printer : 40 / 80 Column Dot Matrix Printer (Printer to be procure optionally)
- Power Supply : DC Adaptor