Technical Specification
-
- Conductivity Range :
● 0-20.00, 20-200.0, 200-2000 µS/cm, 2-20.000, 20-200, 200-2000 mS/cm for K=1.0
● 0-10.00, 10-100.0, 100-1000 µS/cm, 1-10.000, 10-100, 100-1000 mS/cm for K=0.5
● 0-2.00, 2-20.0, 20-200, 200-2000 µS/cm, 2-20, 20-200 mS/cm for K=0.1
(Range value change depending upon cell selection) - Conductivity Resolution : 0.001, 0.01, 0.1 µS/cm & 0.001, 0.01, 0.1, 1 mS/cm
- TDS Range : 0 to 10, 100, 1000, 10000 ppm, 100ppt, 1000ppt
(Depending on TDS Factor) - TDS Resolution : 0.001, 0.01, 0.1 ppm & 0.001, 0.01, 0.1 ppt (1ppt=1000ppm)
- Temperature Range : -5.0 to 130.0°C
- Temperature Resolution : 0.1°C
- Temperature Compensation : Auto / Manual
- Temperature Coefficient : Six – 0-10.000 % per °C (Adjustable) – One Per Range
- Conductivity Range :
- Temperature Calibration : In-built software and can be calibrated by users
- Number of Range : Six
- Calibration Standard : Six Conductivity & TDS Standard – One Per Range
-
- Calibration Factor : Six – One Per Range
- Range Selection : Auto / Manual
- Suitable Cell Constant : 0.1, 0.5 & 1.0 K
- Adjustable Cell Constant : 0.09 to 0.11 K, 0.45 to 0.55 K & 0.90 to 1.1 K
- Conductivity to TDS Conversion : 0.40000 to 1.00000 (Adjustable Factor)
- Reading : Conductivity at actual temperature and at 25°C and TDS with scrolling display.
- TDS Calibration & Analysis : In Separate Mode
- Error Messages : “Wrong Standard / Cell”, “Cell Short”, “Cell Open”, “Try Upper Range”, “Try Lower Range”, “Temperature Probe Error” & “Low Memory”
- Display : 16 x 2 Line Alphanumeric Backlit LCD.
- Keypad : Membrane waterproof polycarbonate soft touch keypad compliance to UL/ROHS.
- Calibration Data Storage : Non-Volatile Memory which can store, print & view with calibration date & time, cell constant, calibration range, standard conductivity solution, measured conductivity at 25°C, actual temperature, calibration factor, instrument serial number, instrument ID, model number etc.
- Analysis Data Storage : More than 500 analysis data which can be viewed & Print, company name, analysis date & time, record number, *Username, *Sample Name, *Bath Number/ID, calibration data with date & time, conductivity at 25°C and conductivity at actual temperature, % Tempco, conductivity to TDS conversion factor, TDS, instrument serial number, Instrument Make & Model & *Signature etc. Secondly, analysis data can be print online without saving analysis data in Instrument.
(*: Not possible to enter data by instrument keypad but it will be handwritten) - Searching of data : With record number by scrolling.
- Report Formation : As per Non-GLP Compliance
- Printer Interface : Centronics Parallel Port / Serial (RS-232 C) Port
- Printer : 40 / 80 Column Dot Matrix Printer (Printer to be procure optionally)
- Power Supply : DC Adaptor